Tag: door

ADA 101 – Ambulatory Accessible Toilet Compartment Doors

ADA 101 info graphic with ADAS 2010 section 604.8.2.2 text and example pictures2010 ADAS Ambulatory Accessible Toilet Compartment Doors

Toilet compartment doors, including door hardware, shall comply with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the compartment and any obstruction shall be 42 inches minimum. The door shall be self-closing. A door pull complying with 404.2.7 shall be placed on both sides of the door near the latch. Toilet compartment doors shall not swing into the minimum required compartment area.

Citation according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

ADA 101 – Maneuvering Clearances at Manual Swinging Doors and Gates

ADA 101 info graphic with ADAS 2010 section 404.2.4.1 code textADAS 2010 404.2.4.1 Maneuvering Clearances at Manual Swinging Doors and Gates.

Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1.

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

ADA 101 – Vision Lights

ADA 101 graphic, blue background, top half contains ADAS 2010 section 404.2.11 Vision Lights text in white lettering, bottom half contains two pictures, left picture is of a non compliant glazed panel in a grey door, the right picture is a graphic of two doors with measurement lines showing compliant glazing panels, below the pictures are a disclaimer to check local accessibility laws, the BlueDAG logo and bluedag.com.

2010 ADAS 404.2.11 – Vision Lights

Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches maximum above the finish floor.

EXCEPTION:Vision lights with the lowest part more than 66 inches from the finish floor or ground shall not be required to comply with 404.2.11.

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards

ADA 101 – Door and Gate Surfaces

404.2.10 Door and Gate Surfaces - Swinging door and gate surfaces within 10 inches of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate. Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch of the same plane as the other. Cavities created by added kick plates shall be capped.

2010 ADAS 404.2.10 – Door and Gate Surfaces

Swinging door and gate surfaces within 10 inches of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate. Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch of the same plane as the other. Cavities created by added kick plates shall be capped.

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

ADA 101 – Door and Gate Opening Force

ADA 101 info graphic with  section 404.2.9 5 code and example pictures 2010 ADAS 404.2.9 – Door and Gate Opening Force

The force for pushing or pulling open a door or gate other than fire doors shall be 5 pounds maximum. The maximum force pertains to the continuous application of force necessary to fully open a door, not the initial force needed to overcome the inertia of the door.

Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.