Tag: elevator

ADA 101 – Elevator Visible Signal Location

ADA 101 info graphic with ADAS 2010 section 407.2.2.2 code textADAS 2010 407.2.2.2 Elevator Signal Location.

Visible signal fixtures shall be centered at 72 inches minimum above the finish floor or ground. The visible signal elements shall be 2 1/2 inches minimum measured along the vertical centerline of the element. Signals shall be visible from the floor area adjacent to the hall call button.

EXCEPTIONS:

1. Destination-oriented elevators shall be permitted to have signals visible from the floor area adjacent to the hoistway entrance.

2. Existing elevators shall not be required to comply with 407.2.2.2.

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

ADA 101 – Elevator Visible and Audible Signals

ADA 101 info graphic with ADAS 2010 section 407.2.2.1 code text and example picturesADAS 2010 407.2.2.1 Elevator Visible and Audible Signals

Visible signal fixtures shall be centered at 72 inches minimum above the finish floor or ground. The visible signal elements shall be 2 1/2 inches minimum measured along the vertical center-line of the element. Signals shall be visible from the floor area adjacent to the hall call button.

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

ADA 101 – Elevator Floor Designation

ADA 101 info graphic with ADAS 2010 section 407.2.3.1 code text and example picturesADAS 2010 407.2.3.1 Elevator Floor Designation

Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances. Floor designations shall be provided in both tactile characters and braille. Tactile characters shall be 2 inches high minimum. A tactile star shall be provided on both jambs at the main entry level.

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.