ADA 101 – Recessed Doors and Gates

Info graphic with ADAS 2010 Section 404.2.4.3 text and example pictures2010 ADAS 404.2.4.3 Recessed Doors and Gates

Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches of the latch side of a doorway projects more than 8 inches beyond the face of the door, measured perpendicular to the face of the door or gate.

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

New Hampshire Governor’s Accessibility Award goes to The Nature Conservancy

The new accessible trail in the Ossipee Pine Barrens

The new accessible trail in the Ossipee Pine Barrens. Photo by Jeff Lougee

Connecting with nature is a path to healing and positive growth for many people.  Creating the infrastructure to help make natural spaces accessible to people of all abilities is an ambitious and worthy effort we can all support.  In recognition of this kind of work, the “New Hampshire Governor’s Commission on Disability recently honored The Nature Conservancy in New Hampshire for the creation of an accessible trail at the Ossipee Pine Barrens Preserve.”

The individuals and organizations chosen to receive the Governor’s Accessibility Award are recognized for their initiatives that embody the mission of the Americans with Disabilities Act.  Awards like these are a great way for public officials to highlight the important work of private and non-profit organizations in helping create accessible communities.  

Source:
Nature Conservancy wins Governor’s Accessibility Award 
By: Staff Writer Sep 24, 2019 Updated Sep 25, 2019
https://www.conwaydailysun.com/business/local/nature-conservancy-wins-governor-s-accessibility-award/article_19f10440-dbc1-11e9-9da3-2b97d479c6d8.html

ADA 101 – Doors in Series and Gates in Series

ADA 101 Info graphic with ADAS 2010 section 404.2.6 text and example pictures ADAS 2010 404.2.6 Doors in Series and Gates in Series

The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches minimum plus the width of doors or gates swinging into the space.

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

ADA 101 – Clear Width at Turn

ADA 101 Info graphic with ADAS 2010 403.5.2 text and example pictures2010 ADAS 403.5.2 Clear Width at Turn

Where the accessible route makes a 180 degree turn around an element which is less than 48 inches wide, clear width shall be 42 inches minimum approaching the turn, 48 inches minimum at the turn and 42 inches minimum leaving the turn.

EXCEPTION: Where the clear width at the turn is 60 inches minimum compliance with 403.5.2 shall not be required.

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

 

ADA 101 – Walking Surface Slope

ADA 101 info-graphic with ADAS 2010 403.3 text and example pictures

2010 ADAS 403.3 Walking Surfaces Slope

The running slope of walking surfaces shall not be steeper than 1:20 (5%). The cross slope of walking surfaces shall not be steeper than 1:48 (2%).

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

ADA 101 – Walking Surfaces Clear Width

ADA 101 info graphic with ADAS 2010 section 403.5.1 text and example pictures2010 ADAS 403.5.1 Walking Surfaces – Clear Width

Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36 inches minimum.

EXCEPTION: The clear width shall be permitted to be reduced to 32 inches minimum for a length of 24 inches maximum provided that reduced width segments are separated by segments that are 48 inches long minimum and 36 inches wide minimum.

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

ADA 101 – Operable Parts

ADA 101 Info-graphic with ADAS 2010 309.4 text and two example pictures.

2010 ADAS 309.4 Operable Parts – Operation

Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5 pounds maximum.

EXCEPTION: Gas pump nozzles shall not be required to provide operable parts that have an activating force of 5 pounds maximum.

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

ADA 101 – Vertical Clearance

ADA 101 Infographic with ADAS 2010 section 307.4 test and example picturesADAS 2010 307.4 – Vertical Clearance

Vertical clearance shall be 80 inches high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches high. The leading edge of such guardrail or barrier shall be located 27 inches maximum above the finish floor or ground.

EXCEPTION: Door closers and door stops shall be permitted to be 78 inches minimum above the finish floor or ground.

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

ADA 101 – Vision Lights

ADA 101 graphic, blue background, top half contains ADAS 2010 section 404.2.11 Vision Lights text in white lettering, bottom half contains two pictures, left picture is of a non compliant glazed panel in a grey door, the right picture is a graphic of two doors with measurement lines showing compliant glazing panels, below the pictures are a disclaimer to check local accessibility laws, the BlueDAG logo and bluedag.com.

2010 ADAS 404.2.11 – Vision Lights

Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches maximum above the finish floor.

EXCEPTION:Vision lights with the lowest part more than 66 inches from the finish floor or ground shall not be required to comply with 404.2.11.

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards