Tag: Reach

ADA 101 – Obstructed High Side Reach

ADA 101 info graphic with ADAS 2010 section 308.3.2 code text and example pictures

2010 ADAS 308.3.2 Obstructed High Side Reach

Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches maximum and the depth of the obstruction shall be 24 inches maximum. The high side reach shall be 48 inches maximum for a reach depth of 10 inches maximum. Where the reach depth exceeds 10 inches, the high side reach shall be 46 inches maximum for a reach depth of 24 inches maximum.

Citation according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

ADA 101 – Obstructed High Forward Reach

ADA 101 info graphic with ADAS 2010 section 308.2.2 code text and example pictures

2010 ADAS 308.2.2 Obstructed High Forward Reach

Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction. The high forward reach shall be 48 inches maximum where the reach depth is 20 inches maximum. Where the reach depth exceeds 20 inches, the high forward reach shall be 44 inches maximum and the reach depth shall be 25 inches maximum.

Citation according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

ADA 101 – Unobstructed Side Reach

ADA 101 info graphic with ADAS 2010 section 308.3.1 code text and example pictures 2010 ADAS 308.3.1 Unobstructed Side Reach

Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches maximum and the low side reach shall be 15 inches minimum above the finish floor or ground.

EXCEPTIONS:
1. An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches maximum.

2. Operable parts of fuel dispensers shall be permitted to be 54 inches maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs.

Citation according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.

ADA 101 – Unobstructed Forward Reach

ADA 101 info graphic with ADAS 2010 section 308.2.1 code textADAS 2010 308.2.1 Unobstructed Forward Reach

Where a forward reach is unobstructed, the high forward reach shall be 48 inches maximum and the low forward reach shall be 15 inches minimum above the finish floor or ground.

Code according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.