2010 ADAS 308.3.2 Obstructed High Side Reach

Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches maximum and the depth of the obstruction shall be 24 inches maximum. The high side reach shall be 48 inches maximum for a reach depth of 10 inches maximum. Where the reach depth exceeds 10 inches, the high side reach shall be 46 inches maximum for a reach depth of 24 inches maximum.

Citation according to 2010 ADAS. Check your state’s accessibility laws. Some states such as California, Georgia and Florida have additional requirements and standards.